ADD ANI AS A TRUSTED SOURCE
googleads
Menu
General News

'ELAC 2 shows no fault warnings, plane begins moving without pilot's input': Former IAF pilot on Airbus A320 software snag

Former Indian Air Force pilot, Captain (Retd) Ehsan Khalid, described the software issue with the Airbus A320 fleet as a performance problem with the Elevator and Aileron Computer 2 (ELAC 2).

ANI Nov 30, 2025 10:01 IST googleads

Captain (Retd) Ehsan Khalid (Photo/ANI)

Noida (Uttar Pradesh) [India], November 30 (ANI): Former Indian Air Force pilot, Captain (Retd) Ehsan Khalid, described the software issue with the Airbus A320 fleet as a performance problem with the Elevator and Aileron Computer 2 (ELAC 2).
Speaking to ANI on the Airbus A320 flight simulator on Saturday, Captain (retd) Ehsan Khalid said that the ELAC 2 system showed no fault warnings, and the plane began moving without the pilot's input.
He said, "There are two flight control computers in the control panel: ELAC 1 and ELAC 2. ELAC 2 is not performing well according to the new software. Its function is to correctly convert the pilot's inputs, control the movement of the surfaces, and monitor faults in the flight control system. If any fault is found, it alerts the pilot so they can fly the plane in accordance with ELAC 1."
"The problem here is that the ELAC 2 system shows no warning of faults and the plane starts movements without the pilot's input," the aviation expert added.
On Saturday, the Directorate General of Civil Aviation (DGCA) issued an airworthiness directive banning the use of multiple Airbus aircraft models following concerns about a safety risk posed by the company's software update.
The Airworthiness directive was applicable for multiple other models of Airbus aircraft, including A319-111, A319-112, A319-113, A319-114, A319-115, A319-131, A319-132, A319-133, A319-151N, A319-153N, A319- 171N, A319-173N, A320-211, A320-212, A320-214, A320-215, A320- 216, A320- 231, A320-232, A320-233, A320-251N, A320-252N, A320-253N, A320-271N, A320-272N, A320- 273N, A321-211, A321- 212, A321-213, A321-231, A321-232, A321-251N, A321-252N, A321- 253N, A321-251NX, A321-252NX, A321-253NX, A321-271N, A321- 272N, A321-271NX and A321-272NX.
The European multinational aerospace company Airbus flagged a potential solar radiation risk, cautioning that intense radiation could corrupt data critical to flight control systems. The company also warned that a significant number of A320 family aircraft currently in service may be affected. Hence, in its statement, Airbus stated that it has been working proactively with aviation authorities to implement the necessary software and hardware protections to ensure the fleet remains safe to operate.
Following this, IndiGo announced the completion of a mandatory Airbus system upgrade across its entire A320-family fleet, confirming that all 200 aircraft are now fully compliant with the latest safety requirements.
Air India Express also said it had completed safety checks on most of its fleet, with the remaining checks to be completed soon. (ANI)

Get the App

What to Read Next

Politics

Giriraj Singh slams Rahul Gandhi over conduct in Parliament

Giriraj Singh slams Rahul Gandhi over conduct in Parliament

Speaking to reporters here on Thursday, Singh said the opposition had sought permission to speak on the issue of LPG, but did not adhere to the subject.

Read More
General News

Fire breaks out at Sheikh Sarai Transport Authority record room

Fire breaks out at Sheikh Sarai Transport Authority record room

A fire broke out at the old Transport Authority building in Sheikh Sarai Phase 2 area of Delhi on Wednesday night, gutting important documents stored in the record room, officials said.

Read More
General News

Tamil Nadu CM Stalin urges citizens' support to tackle LPG crisis

Tamil Nadu CM Stalin urges citizens' support to tackle LPG crisis

In a post on X, Stalin stated that he had written to Prime Minister Narendra Modi and the relevant Union Ministers regarding the issue. He added that the state government held a consultation meeting yesterday under the leadership of R Sakkarapani to discuss strategies for addressing the gas shortage.

Read More
General News

Shinde on bomb threat emails to blow BSE, Vidhan Bhavan

Shinde on bomb threat emails to blow BSE, Vidhan Bhavan

Maharashtra Deputy Chief Minister Eknath Shinde stated that the threats were bogus, calling the Vidhan Bhavan safe and added that operations to tackle the issue are underway smoothly.

Read More
General News

Indian Railways deploys advanced AI and Machine Learning

Indian Railways deploys advanced AI and Machine Learning

Indian Railways is actively enhancing its safety and operational efficiency through the deployment of advanced Artificial Intelligence (AI) and Machine Learning (ML) devices and smart monitoring systems.

Read More
Home About Us Our Products Advertise Contact Us Terms & Condition Privacy Policy

Copyright © aninews.in | All Rights Reserved.